A rotation by θ about a unit axis n acts on a spin-half state as
U = cos(θ/2) I − i sin(θ/2) n·σ
At θ = 360° this is −I: every state vector changes sign, and the density matrix ρ, which fixes every probability, does not change. In a balanced interferometer with the rotation in one arm and an extra path phase φ in the other,
P(bright) = [1 + Re(e^{iφ} Tr(ρU))] / 2, Tr(ρU) = cos(θ/2) − i sin(θ/2) n·r
where r is the spin (Bloch) vector of the entering state. For sideways spin (+x) rotated about z, Tr(ρU) = cos(θ/2): P(bright) is 1, 0.5, 0, 0.5 and 1 at 0°, 180°, 360°, 540° and 720°. With the same rotation in both arms the arms differ by no rotation, so Tr(ρ U†U) = 1. Simulated counts are drawn at random from these probabilities with a seeded generator.
Read the numerical model · Validation record